Verify that the approximate resistance, shown in the following table on page 17, is within ambient temperature range. ---If the resistance is within the range shown in the table, go to step 6. ---If the resistance is infinite or close to zero, replace the temperature thermistor assembly.For a better experience, please enable JavaScript in your browser before proceeding.
After replacing the 45.00 part, it still wont switch over to warm or hot water. I felt comfortable replacing the inlet valve and inspecting the hoses and wiring for loose connections. If it does require a control panel Im probably going to pass and move on. I would also mention that when on hot water setting, the water comes out cold. When I turn off the cold feed while still on hot, nothing comes out. And, I also disconnected the hot feed into the washer and ran it into a bucket and I got plenty of hot water. Whirlpool Wtw5300Vw Repair Manual Test FromOther than that, the hot water came out while doing the manual test from page 13. It really wasnt a reset per say, but running that HOT water and COLD water manual test just verifies both come on like they should. I can get hot water to dispense when running the test functions you referred me to but, I cant get hot water to dispense when trying to run a regular wash cycle. Do you think it could be the temperature selection switch About ready to toss this 19 month old washer Thanks for your help. When you start a normal load on HOT, turn OFF the COLD side faucet and see how much it fills with hot. Jake. Shutting off the cold feed when on the hot setting results with no water at all. Ran the test sequence again and was able to get hot water no problem. What you do is get a multimeter and set it on Volts AC then set the temperature on HOT only and start the washer, then put your meter probes on the two HOT side solenoid electrical terminals and see if your meter reads 120 volts, if so and if NO HOT water is coming out, then that water inlet valve you got is defective. Thats what happened to my local customer, their NEW water inlet valve was defective, and I asked them where they got it from and they mentioned a company Ive never heard of before, so they got their money back and I installed the OEM water inlet valve that I had on my truck and it worked perfect, and they havent called back to say it stopped working again. I get all my parts from AppliancePartsPros and RepairClinic. Heres the OEM water inlet valve for your model you can order: Water Inlet Valve W11210459. It was about the same price and part as the one you referred me to. Maybe Ill try another inlet valve and let you know how I make out. Whirlpool Wtw5300Vw Repair Manual Test ModeCheck the hot valve by performing Hot Valve test under Manual Test Mode on page 9. If hot water is being dispensed, proceed to step 3. Unplug washer or disconnect power. Remove console to access main control. Remove connector J9 from the main control. With an ohmmeter, measure the resistance of the temperature thermistor between pins J9-3 and J9-7. Verify that the approximate resistance, shown in the following table on page 17, is within ambient temperature range. If the resistance is within the range shown in the table, go to step 6. If the resistance is infinite or close to zero, replace the temperature thermistor assembly.
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |